Input Voltage
28 VDC Nominal
22-37 VDC Normal
15-38 VDC Abnormal

Output Voltage
115 VAC +/- 2.0% or
230 VAC +/- 2.0% or
115/200 VAC Three Phase WYE or
115 VAC L-L Three Phase Delta

26VAC Output on 400Hz models
  Output Frequency
50 Hz +/- 1% or
60 Hz +/- 1% or
400 Hz +/- 1%

Output Power
20 VA to 37500 VA

Overload
110% for 2 Hours
125% for 5 Minutes
200% Rated Short Circuit Current
  Output Wave Form
Sinewave THD< 2%
Crest Factor
1.41 +/- 0.04
DC Content < 0.1 VDC

Efficiency
80% Typical

Power Factor
0.75 Lag to 0.8 Lead
Not Damaged by Any Power Factor